N2XCY
Power and signal cable 0,6/1 kV, XLPE insulated, PVC sheathed, with concentric protective Cu conductor
|
JUS mark:XP40
|
|
|
Application |
Standards |
|
Application
Distribution and signal power cable for static application in ground, in water, within facilities, in cable canals, in concrete, in conditions where there is a danger of possible mechanical damages, but where the cable is not exposed either to systematic mechanical stress or heavier tensile strain.
Concentric conductor can be used as neutral, protective or earth connection, and in conditions where it is exposed to danger of damages caused by digging, it acts as protection against contact voltage, in case of rough insulation damage.
Used in transformer stations, industrial plants, metropolitan networks and in other electric plants where heavier current and thermal loads are expected (operating temperature of conductor up to 90 °C).
|
HRN HD 603 S1
IEC 60502-1
DIN VDE 0276 part 603
cables with 6 and more conductors:
HRN HD 627 S1
DIN VDE 0276-627
|
|
Construction |
|
Technical data |
Conductor: |
Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295 |
class 1: |
solid, round (RE) |
class 2: |
multi wire stranded, round (RM) or sector (SM), multi wire exceeding 50 mm² are compacted |
Insulation: |
XLPE-compound DIX 3 acc. to HRN HD 603 S1, concentrically stranded cores, colour marked acc. to HRN HD 308 S2 / VDE 0293-308 |
Concentric conductor: |
in inner layer spirally wrapped round copper wires, in external layer copper tape wrapped in counter-helix |
Filler: |
extruded elastomer or plastomer compound or wrapped thermoplastic tapes |
Sheath: |
PVC compound DMV-6 acc. to HRN HD 603 S1 |
sheath colour: |
black |
|
|
Core colour marking: |
HRN HD 308 S2 / VDE 0293-308 |
|
Temperature range: |
|
during installation:
|
-5 °C up to +50 °C |
fixed installed: |
-20 °C up to +90 °C |
at short circuit of max. 5 s: |
up to 250 °C |
Nominal voltage: |
Uο/U = 0,6/1 kV |
Test voltage: |
4 kV |
Maximal tensile strength: |
50 N/mm²
|
Behaviour in fire: |
IEC 60332-1 |
Minimal inner bending radius: |
|
single core: |
15D |
multi core: |
12D |
Dimensions – number of cores x conductor cross-section |
Construction |
External diameter |
Insulation thickness |
Sheath thickness |
Conductor resistance at 20 °C |
Short circuit current 1s |
Cu weight |
Cable weight |
Packing* |
|
|
approx. |
nominal |
nominal |
max. |
nominal |
|
approx. |
CUT |
N x mm²
|
|
mm |
mm |
mm |
Ω/km |
kA |
kg/km |
kg/km |
CUT |
2 x 1,5/1,5 |
RE |
13 |
0,7 |
1,8 |
12,1 |
0,214 |
52 |
200 |
CUT |
2 x 2,5/2,5 |
RE |
13,9 |
0,7 |
1,8 |
7,41 |
0,357 |
80 |
260 |
CUT |
2 x 4/4 |
RE |
16 |
0,7 |
1,8 |
4,61 |
0,573 |
123 |
350 |
CUT |
|
3 x 1,5/1,5 |
RE |
17 |
0,7 |
1,8 |
12,1 |
0,214 |
66 |
220 |
CUT |
3 x 2,5/2,5 |
RE |
18 |
0,7 |
1,8 |
7,41 |
0,357 |
104 |
280 |
CUT |
3 x 4/4 |
RE |
20 |
0,7 |
1,8 |
4,61 |
0,573 |
161 |
390 |
CUT |
3 x 16,/16 |
RE |
20,1 |
0,7 |
- |
1,15 |
2,29 |
643 |
880 |
CUT |
3 x 25/16 |
RM |
25,7 |
0,9 |
- |
0,727 |
3,58 |
902 |
1378 |
CUT |
3 x 35/16 |
SM |
27,8 |
0,9 |
- |
0,524 |
5,01 |
1190 |
1705 |
CUT |
3 x 50/25 |
SM |
30,9 |
1 |
- |
0,387 |
7,15 |
1723 |
2237 |
CUT |
3 x 70,/35 |
SM |
35,3 |
1,1 |
- |
0,268 |
10,01 |
2410 |
3055 |
CUT |
3 x 95/50 |
SM |
38,9 |
1,1 |
- |
0,193 |
13,59 |
3296 |
4058 |
CUT |
3 x 120/70 |
SM |
43,1 |
1,2 |
- |
0,153 |
17,16 |
4236 |
5091 |
CUT |
3 x 150/70 |
SM |
47,4 |
1,4 |
- |
0,124 |
21,45 |
5100 |
6108 |
CUT |
3 x 185/95 |
SM |
52,6 |
1,6 |
- |
0,0991 |
26,46 |
6383 |
7587 |
CUT |
3 x 240/120 |
SM |
58,7 |
1,7 |
- |
0,0754 |
34,32 |
8242 |
9817 |
CUT |
|
4 x 1,5/1,5 |
RE |
18 |
0,7 |
1,8 |
12,1 |
0,214 |
81 |
250 |
CUT |
4 x 2,5/2,5 |
RE |
19 |
0,7 |
1,8 |
7,41 |
0,357 |
128 |
340 |
CUT |
4 x 4,/4 |
RE |
21 |
0,7 |
1,8 |
4,61 |
0,573 |
200 |
460 |
CUT |
4 x 6/6 |
RE |
22 |
0,7 |
1,8 |
3,08 |
0,858 |
297 |
580 |
CUT |
|
5 x 1,5/1,5 |
RE |
16 |
0,7 |
1,8 |
12,1 |
0,214 |
95 |
330 |
CUT |
5 x 2,5/2,5 |
RE |
17 |
0,7 |
1,8 |
7,41 |
0,357 |
152 |
400 |
CUT |
5 x 4,/4 |
RE |
19 |
0,7 |
1,8 |
4,61 |
0,573 |
238 |
550 |
CUT |
|
7 x 1,5/2,5 |
RE |
19 |
0,7 |
1,8 |
12,1 |
0,214 |
133 |
350 |
CUT |
10 x 1,5/2,5 |
RE |
23 |
0,7 |
1,8 |
12,1 |
0,214 |
176 |
410 |
CUT |
12 x 1,5/2,5 |
RE |
24 |
0,7 |
1,8 |
12,1 |
0,214 |
205 |
470 |
CUT |
14 x 1,5/2,5 |
RE |
25 |
0,7 |
1,8 |
12,1 |
0,214 |
234 |
520 |
CUT |
16 x 1,5/1,5 |
RE |
26 |
0,7 |
1,8 |
12,1 |
0,214 |
276 |
620 |
CUT |
19 x 1,5/4 |
RE |
28 |
0,7 |
1,8 |
12,1 |
0,214 |
320 |
660 |
CUT |
21 x 1,5/6 |
RE |
22 |
0,7 |
1,8 |
12,1 |
0,214 |
276 |
620 |
CUT |
24 x 1,5/6 |
RE |
31 |
0,7 |
1,8 |
12,1 |
0,214 |
413 |
850 |
CUT |
30 x 1,5/6 |
RE |
32 |
0,7 |
1,8 |
12,1 |
0,214 |
499 |
1020 |
CUT |
40 x 1,5/10 |
RE |
36 |
0,7 |
1,8 |
12,1 |
0,214 |
696 |
1280 |
CUT |
52 x 1,5/10 |
RE |
38 |
0,7 |
1,8 |
12,1 |
0,214 |
869 |
1600 |
CUT |
61 x 1,5/10 |
RE |
40 |
0,7 |
1,8 |
12,1 |
0,214 |
998 |
2000 |
CUT |
|
7 x 2,5/2,5 |
RE |
21 |
0,7 |
1,8 |
7,41 |
0,357 |
200 |
450 |
CUT |
10 x 2,5/4 |
RE |
25 |
0,7 |
1,8 |
7,41 |
0,357 |
286 |
600 |
CUT |
12 x 2,5/4 |
RE |
25 |
0,7 |
1,8 |
7,41 |
0,357 |
334 |
660 |
CUT |
14 x 2,5/6 |
RE |
26 |
0,7 |
1,8 |
7,41 |
0,357 |
403 |
750 |
CUT |
16 x 2,5/4 |
RE |
27 |
0,7 |
1,8 |
7,41 |
0,357 |
451 |
800 |
CUT |
19 x 2,5/6 |
RE |
29 |
0,7 |
1,8 |
7,41 |
0,357 |
523 |
940 |
CUT |
24 x 2,5/10 |
RE |
33 |
0,7 |
1,8 |
7,41 |
0,357 |
696 |
1300 |
CUT |
30 x 2,5/10 |
RE |
35 |
0,7 |
1,8 |
7,41 |
0,357 |
840 |
1600 |
CUT |
40 x 2,5/10 |
RE |
39 |
0,7 |
1,8 |
7,41 |
0,357 |
1080 |
1660 |
CUT |
52 x 2,5/10 |
RE |
40 |
0,7 |
1,8 |
7,41 |
0,357 |
1368 |
2000 |
CUT |
61 x 2,5/10 |
RE |
42 |
0,7 |
1,8 |
7,41 |
0,357 |
1584 |
2280 |
CUT |
|
7 x 4,/4 |
RE |
23 |
0,7 |
1,8 |
4,61 |
0,573 |
315 |
600 |
CUT |
10 x 4/6 |
RE |
27 |
0,7 |
1,8 |
4,61 |
0,573 |
451 |
900 |
CUT |
|
12 x 4/6 |
RE |
27 |
0,7 |
1,8 |
4,61 |
0,573 |
528 |
1060 |
CUT |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length