A-2Y(L)2Y
Telecommunications underground cable for outdoor application, with PE insulation and PE laminated sheath, transversally watertight
|
similar cables:
F-2YA2Y
TK 33 A
|
|
|
Application |
Standards |
|
This telecommunications cable is applied as subscriber cable for connection of local telephone extensions with telephone exchanges or in industrial plants. Possible laying in ground, in cable conduits, same as within premises. Sheath resistant to UV-irradiation and together with aluminium protection transversally watertight. The cable is not intended for supply purposes.
|
DIN VDE 0816
|
|
Construction |
|
Technical data |
Conductor: |
bare solid copper conductor, of 0,4; 0,6 or 0,8 mm diameter |
Insulation: |
PE (polyethylene) compound of type 2YI1, acc. to DIN VDE 0207, per 4 conductors are twisted in star-quad, and 5 star-quads are stranded in a basic bundle, 5 or 10 basic bundles are stranded in a main bundle, where the first basic bundle, serving for number coding, is spirally wrapped with a narrow red plastic tape, and all the other with a white tape, core colour marking is defined acc. to DIN VDE 0816, conductors in star-quad are of the same colour, each conductor with a different number of black rings |
Separator: |
plastic tape |
Protection: |
(ensures transversal water-tightness and protects electric screen against external impacts) aluminium tape 0,15 mm, longitudinally connected with overlap, both sides coated with PE-copolymer and longitudinally spliced with the sheath – making together a laminated sheath |
Sheath: |
PE-compound 2YM2 acc. to VDE 0207 |
marks on sheath: |
hyphens for meter length marking, telephone handset sign |
sheath colour: |
black |
Temperature range: |
|
during application:
|
-20 °C up to +50 °C |
fixed installed: |
-30 °C up to +70 °C |
|
Test voltage: |
|
core - core: |
500 V |
core - screen: |
2000 V |
Insulation resistance: |
min. 5 GΩ/km |
Capacitance unbalance: |
(at 800 Hz, 100% of value, max. 800 pF/300m |
Min. inner bending radius: |
|
during laying or with repeated bending with stress: |
10D |
single bending without stress: |
5D |
Dimensions - number of
cores x conductor diameter |
External diameter |
Sheath thickness |
Cu weight |
Cable weight |
Packing* |
|
approx. |
nominal |
|
approx. |
|
N x mm² |
mm |
mm |
kg/km |
kg/km |
|
6 x 2 x 0,4 |
9,5 |
1,8 |
15 |
100 |
CUT |
10 x 2 x 0,4 |
11,0 |
1,8 |
25 |
115 |
CUT |
20 x 2 x 0,4 |
13,0 |
1,8 |
50 |
165 |
CUT |
30 x 2 x 0,4 |
15,0 |
1,8 |
75 |
215 |
CUT |
40 x 2 x 0,4 |
16,0 |
1,8 |
101 |
260 |
CUT |
50 x 2 x 0,4 |
17,0 |
1,8 |
126 |
305 |
CUT |
70 x 2 x 0,4 |
19,0 |
1,8 |
176 |
385 |
CUT |
100 x 2 x 0,4 |
21,0 |
1,8 |
251 |
510 |
CUT |
150 x 2 x 0,4 |
25,0 |
1,8 |
377 |
705 |
CUT |
200 x 2 x 0,4 |
28,0 |
2,0 |
503 |
905 |
CUT |
250 x 2 x 0,4 |
30,5 |
2,0 |
629 |
1095 |
CUT |
300 x 2 x 0,4 |
33,0 |
2,0 |
754 |
1280 |
CUT |
350 x 2 x 0,4 |
35,0 |
2,0 |
880 |
1490 |
CUT |
400 x 2 x 0,4 |
37,5 |
2,2 |
1006 |
1670 |
CUT |
500 x 2 x 0,4 |
41,0 |
2,2 |
1257 |
2030 |
CUT |
600 x 2 x 0,4 |
44,5 |
2,2 |
1508 |
2390 |
CUT |
700 x 2 x 0,4 |
48,5 |
2,6 |
1760 |
2805 |
CUT |
800 x 2 x 0,4 |
51,0 |
2,6 |
2011 |
3160 |
CUT |
1000 x 2 x 0,4 |
57,0 |
2,6 |
2514 |
3965 |
CUT |
1200 x 2 x 0,4 |
61,0 |
3,0 |
3017 |
4645 |
CUT |
|
2 x 2 x 0,6 |
9,0 |
|
11 |
80 |
CUT |
4 x 2 x 0,6 |
11,0 |
|
23 |
120 |
CUT |
6 x 2 x 0,6 |
12,0 |
1,8 |
34 |
130 |
CUT |
10 x 2 x 0,6 |
13,5 |
1,8 |
57 |
155 |
CUT |
20 x 2 x 0,6 |
16,0 |
1,8 |
113 |
240 |
CUT |
30 x 2 x 0,6 |
18,0 |
1,8 |
170 |
310 |
CUT |
40 x 2 x 0,6 |
20,0 |
1,8 |
226 |
385 |
CUT |
50 x 2 x 0,6 |
21,0 |
1,8 |
283 |
460 |
CUT |
70 x 2 x 0,6 |
25,0 |
1,8 |
396 |
605 |
CUT |
100 x 2 x 0,6 |
28,0 |
2,0 |
565 |
870 |
CUT |
150 x 2 x 0,6 |
33,0 |
2,0 |
848 |
1345 |
CUT |
200 x 2 x 0,6 |
38,0 |
2,2 |
1131 |
1755 |
CUT |
250 x 2 x 0,6 |
41,0 |
2,2 |
1414 |
2140 |
CUT |
300 x 2 x 0,6 |
44,5 |
2,2 |
1696 |
2525 |
CUT |
350 x 2 x 0,6 |
47,5 |
2,6 |
1979 |
2930 |
CUT |
400 x 2 x 0,6 |
51,0 |
2,6 |
2262 |
3300 |
CUT |
500 x 2 x 0,6 |
56,0 |
2,6 |
2827 |
4050 |
CUT |
600 x 2 x 0,6 |
60,0 |
3,0 |
3392 |
4770 |
CUT |
700 x 2 x 0,6 |
64,0 |
3,0 |
3958 |
5500 |
CUT |
800 x 2 x 0,6 |
69,0 |
|
4523 |
6350 |
CUT |
1000 x 2 x 0,6 |
75,0 |
|
5654 |
7550 |
CUT |
1200 x 2 x 0,6 |
81,0 |
|
6785 |
9300 |
CUT |
|
2 x 2 x 0,8 |
9,0 |
|
20 |
90 |
CUT |
4 x 2 x 0,8 |
12,0 |
|
40 |
140 |
CUT |
6 x 2 x 0,8 |
13,0 |
1,8 |
60 |
160 |
CUT |
10 x 2 x 0,8 |
15,0 |
1,8 |
101 |
210 |
CUT |
20 x 2 x 0,8 |
18,5 |
1,8 |
201 |
355 |
CUT |
30 x 2 x 0,8 |
21,0 |
1,8 |
302 |
475 |
CUT |
40 x 2 x 0,8 |
23,0 |
1,8 |
402 |
600 |
CUT |
50 x 2 x 0,8 |
26,0 |
1,8 |
503 |
745 |
CUT |
70 x 2 x 0,8 |
29,0 |
2,0 |
704 |
1100 |
CUT |
100 x 2 x 0,8 |
34,0 |
2,0 |
1005 |
1425 |
CUT |
150 x 2 x 0,8 |
40,0 |
2,2 |
1508 |
2200 |
CUT |
200 x 2 x 0,8 |
44,0 |
2,2 |
2011 |
2900 |
CUT |
250 x 2 x 0,8 |
51,0 |
2,2 |
2514 |
3550 |
CUT |
300 x 2 x 0,8 |
53,0 |
2,6 |
3016 |
4200 |
CUT |
350 x 2 x 0,8 |
56,0 |
2,6 |
3519 |
4900 |
CUT |
400 x 2 x 0,8 |
60,0 |
3,0 |
4022 |
5500 |
CUT |
500 x 2 x 0,8 |
68,0 |
3,0 |
5027 |
6800 |
CUT |
600 x 2 x 0,8 |
74,0 |
|
6032 |
8100 |
CUT |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length