Cables for loudspeakers

Marks: (N)YFAZ
LFZ-XY

Cables for loudspeakers
Application

Application

 

Cables for application in dry premises, permanently flexible, but able to sustain very low mechanical strains. Mostly used for loudspeakers, in households or in public building.


Datasheet Cables for loudspeakers

Construction

Construction

Technical data

Technical data

Conductor: 2 parallel laid copper conductors, fine wired stranded, class 5 (for NYFAZ) or class 6 (for LFZ-XY) acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: soft flexible PVC, 8-shaped cross-section of insulation, easily detached one conductor from another
insulation colour: one conductor black, the other conductor red, transparent, one conductor marked with longitudinal coloured line, also possible different insulation colours
Temperature range:  
during installation:
-5 °C up to +70 °C
fixed installed: -30 °C up to +70 °C
Nominal voltage: 300 V
Insulation resistance: min. 20 MΩ x km
Behaviour in fire: IEC 60332-1



Dimensions - nominal cross-section Insulation colours Dimensions - number of cores x conductor diameter External diameter Conductor resistance at 20°C Inductance Cu weight Cable weight Packing*
    nominal approx. max. approx.   approx.  
N x mm²   n x mm mm Ω/km [µH/m] kg/km kg/km  
2 x 0,5 rd/bk 16 x 0,20 2,4 x 4,8 390   9,6 21 c.100
2 x 0,75 rd/bk 24 x 0,20 2,5 x 5 260 0,57 14,4 29 c.100
2 x 1 rd/bk 32 x 0,20 2,6 x 5,2 19,50   19,2 32 c.100
2 x 1,5 rd/bk 30 x 0,25 2,7 x 5,6 13,30 0,55 28,8 42 c.100
2 x 1,5 transp 84 x 0,15 2,7 x 5,6 13,30 0,55 28,8 42 c.100
2 x 1,5 transp 192 x 0,10 2,7 x 5,6 13,30 0,55 28,8 42 c.100
2 x 2,5 rd/bk 50 x 0,25 3,6 x 7,4 7,98 0,53 48 61 c.100
2 x 2,5 transp 140 x 0,15 3,6 x 7,4 7,98 0,53 48 61 c.100
2 x 2,5 transp 320 x 0,10 3,6 x 7,4 7,98 0,53 48 61 c.100
2 x 4 rd/bk 56 x 0,30 4,5 x 9,7 4,95 0,51 76,8 110 c.100
2 x 4 transp 224 x 0,15 4,5 x 9,7 4,95 0,51 76,8 110 c.100
2 x 4 transp 512 x 0,10 4,5 x 9,7 4,95 0,51 76,8 110 c.100
2 x 6 transp 192 x 0,20 6,1 x 12,5 3,30 0,50 115,2 141 c.100
2 x 6 transp 336 x 0,15 6,1 x 12,5 3,30 0,50 115,2 141 c.100
2 x 6 transp 768 x 0,10 6,1 x 12,5 3,30 0,50 115,2 141 c.100
2 x 10 transp 560 x 0,15 7 x 15 1,95 0,49 192 250 c.100
2 x 10 transp 1.280 x 0,10 7 x 15 1,95 0,49 192 250 c.100

*) Packing: c.100 = coli 100 m


Products