RG 174 A/UCoaxial cable |
|
Application |
Standards |
|
Coaxial cables are applied for broadband transmission of radio, TV, video and data signals. Applicable up to GHz-a level, with low attenuation and low signal distortion. RG174 coaxial cable is applied for inst. for short-distance radio signals, and in all circumstances of restricted area requiring a small cable cross-section. Polyethylene of low dielectric constant enables high-speed signal diffusion, and good flexibility at installation. Permitted only indoor application, exceptionally also outdoor, under protection against sunlight. |
MIL-C-17F |
RG 174 A/U 50 Ω 75 Ω |
Construction |
Technical data |
Concentric conductors, insulation (dielectric) and sheath. Cable retains its function if inner and external conductor are at exact constant distance, without any cable bending. | ||
Inner conductor: | copper-clad steel wires, bimetal, stranded, diameter 0,48 ± 0,01 mm, 7 x 0,16 mm | |
Insulation (dielectric): | polyethylene, external diameter 1,52 ± 0,05 mm | |
External conductor: | braid of tinned copper wires 0,16 mm, 87% optical overlap | |
Sheath: | PVC, external diameter 2,7 ± 0,10 mm | |
sheath colour: | black |
Temperature range: | ||
during installation: |
-15 °C up to +55 °C | |
operating temp.: | -40 °C up to +85 °C | |
Min. inner bending radius: | ||
without load: | 5D (14 mm) | |
under load: | 10D (27 mm) | |
Behaviour in fire: | IEC 60332-1 | |
Maximal tensile strength: | 35 N | |
Cable weight: | 11,2 kg/km | |
Copper weight: | 5,9 kg/km | |
Electrical characteristics: | ||
Frequency | Attenuation at 20 °C | Max. permitted strength (at outdoor temperature of 25 °C and max. conductor temperature of 70 °C) |
MHz | dB/100 | W |
10 | 9,5 | 240 |
100 | 31,0 | 68 |
200 | 51,0 | 45 |
400 | 74,0 | 32 |
1000 | 120,0 | 18 |
2000 | 170,0 | 11 |
3000 | 210,0 | 9 |
Frequency | Losses in return loop |
MHz | dB |
50 - 300 | ≥ 23 |
300 - 1000 | ≥ 21 |