RG 59 B/UCoaxial cable |
|
Application |
Standards |
|
Coaxial cables are applied for broadband transmission of radio, TV, video and data signals. Applicable up to GHz-a level, with low attenuation and low signal distortion. RG59 coaxial cable is applied for inst. for video-signal, but not at larger distances. Foamed polyethylene of low dielectric constant enables high-speed signal diffusion, and good flexibility at installation. Permitted only indoor application, exceptionally also outdoor, under protection against sunlight. |
MIL-C-17F |
RG 59 B/U 75 Ω |
Construction |
Technical data |
Concentric conductors, insulation (dielectric) and sheath. Cable retains its function if inner and external conductor are at exact constant distance, without any cable bending. | ||
Inner conductor: | copper-clad steel wire, bimetal, diameter 0,59 ± 0,01 mm (20 AWG) | |
Insulation (dielectric): | PE, external diameter 3,70 ± 0,05 mm | |
External conductor: | braid of bare copper wires 0,16 mm, 95% optical overlap | |
Sheath: | PVC, external diameter 6,15 ± 0,10 mm | |
sheath colour: | black |
Temperature range: | ||
during installation: |
-15 °C up to +55 °C | |
operating temp.: | -40 °C up to +85 °C | |
Min. inner bending radius: | ||
without load: | 5D (31 mm) | |
under load: | 10D (62 mm) | |
Behaviour in fire: | IEC 60332-1 | |
Maximal tensile strength: | 145 N | |
Cable weight: | 53,6 kg/km | |
Copper weight: | 24,7 kg/km | |
Electrical characteristics: | ||
Frequency | Attenuation at 20 °C | Max. permitted strength (at outdoor temperature of 25 °C and max. conductor temperature of 70 °C) |
MHz | dB/100 | W |
10 | 3,5 | 1100 |
100 | 11,0 | 340 |
200 | 16,0 | 230 |
400 | 24,0 | 180 |
1000 | 38,0 | 105 |
2000 | 60,0 | 58 |
3000 | 78,0 | 45 |
Frequency | Losses in return loop |
MHz | dB |
50 - 300 | ≥ 30 |
300 - 1000 | ≥ 26 |