U-DQ(ZN)BHCentral loose tube, optical cable for universal application (indoor and outdoor), with reinforcement and anti-rodent protection |
|
Application |
Standards |
|
This cable can be used for LAN and WAN system backbones, telecommunications connection lines, FTTB (fiber to the business, fiber to the building) connection lines, same as for FTTH (fiber to the home) house connections. Fire-resistant, watertight and UV-resistant sheath makes it ideal for mixed indoor and outdoor installations. Can be laid in cable canals and on trays. Can be installed in tubes by blow in-procedure. Glass fibers provide resistance to tensile strains (specially versions for 1,5 and 3,0 kN) and to a certain degree serve as anti-rodent protection. Versions for 1,5 and 3,0 kN can be laid directly in ground, with adequate sand bedding. |
ISO/IEC 11801 |
U-DQ(ZN)BH 117.09 Kb |
Construction |
Technical data |
Fiber: | 2 - 24 fibers (of 250 μm) with coloured primary coating | |
Loose tube: | of elastomer, filled with jelly, of diameter 2,8 mm for 2 - 16 fibers; or 3,5 mm for 24 fibers, loose laid fibers within tube | |
Supporting element and anti-rodent protection: | glass fibers or aramid threads, filled area around tube (for versions with larger tensile strength, 1,5 or 3 kN, more glass fibers or aramid threads are added) | |
Watertight element: | swelling tape | |
Sheath: | LSHF halogen-free compound, resistant to UV-irradiation, of 1,0 - 1,8 mm thickness | |
Fiber | colour marking: | |
Temperature range: | |
operating temp.: | -30 °C up to +60 °C |
during installation: | -15 °C up to +40 °C |
at storage: | -40 °C up to +60 °C |
Behaviour in fire: | |
Flame retardant: | IEC 60332-1 |
Halogen-free: | IEC 60754-1 |
Non-corrosive combustion gases: | IEC 60754-2 |
minimal smoke release: | IEC 61034-2 |
Resistance to torsion: | 5 ± 1 turn / 1 m |
Number of optical fibers | External cable diameter | Permitted fire load | Permitted fire load | Constant tensile strength | Short-term tensile strength (several days) | Tensile strength at installation (several hours) | Resistance to pressure | Resistance to impacts | Cable weight |
max. | max. | max. | max. | max. | max. | max. | |||
mm | MJ/km | KWh/m | N | N | N | N | Nm | kg/km | |
1 kN | |||||||||
2 - 16 | 6 | 630 | 0,18 | 500 | 750 | 1000 | 1500 | 15 | 40 |
18 - 24 | 6,5 | 800 | 0,22 | 500 | 750 | 1000 | 1500 | 15 | 45 |
1,5 kN | |||||||||
2 - 16 | 7,5 | 1100 | 0,31 | 700 | 1000 | 1500 | 2000 | 20 | 55 |
18 - 24 | 8 | 1300 | 0,36 | 700 | 1000 | 1500 | 2000 | 20 | 60 |
3 kN | |||||||||
2 - 16 | 9 | 1300 | 0,36 | 1000 | 2000 | 3000 | 3000 | 25 | 80 |
18 - 24 | 9,5 | 1460 | 0,41 | 1000 | 2000 | 3000 | 3000 | 25 | 85 |