JE-Y(St)Y
Cable for data transmission in industrial electronics, PVC insulated and sheathed, with Al-foil
|
|
|
|
Application |
Standards |
|
Cable with protective screen against electromagnetic impacts, for transmission of analogue and digital signals, suitable for fixed and mobile installations in device production, for electronic, computer and measurement systems, in mobile and production conveyers, for office devices. Usage with shifting is only possible if not exposed to stress and mechanical loads. Laid in dry and damp premises, but outdoor application is not recommended, except in special cases under protection against direct sunlight. Not for direct laying in ground or water, not intended for supply purposes.
|
DIN VDE 0815
|
|
Construction |
|
Technical data |
Conductor: |
bare copper conductor, class 1 (solid), of 0,8 mm diameter (cross-section 0,5 mm²) |
Insulation: |
PVC compound of type YI1 or YI3, acc. to DIN VDE 0207 part 4, conductors twisted in pairs, per 4 pairs are stranded in bundle, bundles are stranded in layers, core colour marking defined acc. to DIN VDE 0815 |
Separator: |
transparent plastic foil |
Electrostatic screen: |
aluminium - laminated polyester tape and copper contact conductor of 0,8 mm diameter |
Sheath: |
PVC-compound YM1 acc. to DIN VDE 0207 part 5 |
sheath colour: |
grey (RAL 7032) or blue (RAL 5015) |
Temperature range: |
|
during installation:
|
-5 °C up to +70 °C |
fixed installed: |
-30 °C up to +70 °C |
Nominal voltage: |
225 V |
Test voltage: |
|
core - core: |
500 V |
core - screen: |
2000 V |
Insulation resistance: |
min. 100 MΩ x km |
Mutual capacitance(at 800 Hz): |
max. 1001) nF/km |
Capacitance unbalance(at 800 Hz): |
max. 200 pF/100m |
Loop resistance at 20°C: |
max. 73,2 Ω/km |
Inductance: |
0,65 mH/km |
Permitted current load: |
5,1 A |
Linear attenuation(at 800 Hz): |
oko 1,1 dB/km |
Min. inner bending radius: |
|
during laying or with repeated bending with stress: |
10D |
single bending without stress: |
5D |
Behaviour in fire: |
IEC 60332-1 |
Dimensions - nominal cross-section |
Sheath thickness |
External diameter |
Conductor resistance at 20 °C |
Cu weight |
Cable weight |
Packing* |
|
nominal |
approx. |
max. |
|
approx. |
|
N x mm² |
mm |
mm |
Ω/km |
kg/km |
kg/km |
|
2 x 2 x 0,8 |
1 |
6,5 |
36 |
25 |
60 |
CUT |
3 x 2 x 0,8 |
1 |
7,8 |
36 |
35 |
78 |
CUT |
4 x 2 x 0,8 |
1 |
8,5 |
36 |
45 |
96 |
CUT |
8 x 2 x 0,8 |
1 |
10,5 |
36 |
85 |
158 |
CUT |
12 x 2 x 0,8 |
1 |
12 |
36 |
126 |
235 |
CUT |
16 x 2 x 0,8 |
1,2 |
14 |
36 |
166 |
295 |
CUT |
20 x 2 x 0,8 |
1,2 |
15 |
36 |
206 |
355 |
CUT |
24 x 2 x 0,8 |
1,2 |
16 |
36 |
246 |
430 |
CUT |
32 x 2 x 0,8 |
1,4 |
19 |
36 |
327 |
555 |
CUT |
40 x 2 x 0,8 |
1,4 |
20,5 |
36 |
407 |
670 |
CUT |
48 x 2 x 0,8 |
1,4 |
23 |
36 |
488 |
740 |
CUT |
80 x 2 x 0,8 |
2 |
29 |
36 |
809 |
1290 |
CUT |
100 x 2 x 0,8 |
2 |
32 |
36 |
1015 |
1495 |
CUT |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length