RG 213 /UCoaxial cable |
|
Application |
Standards |
|
Coaxial cables are applied for broadband transmission of radio, TV, video and data signals. Applicable up to GHz-a level, with low attenuation and low signal distortion. RG213 coaxial cable is applied for inst. for radio signal transmission. Suitable for larger distances. Polyethylene of low dielectric constant enables high-speed signal diffusion, and good flexibility at installation. Permitted only indoor application, exceptionally also outdoor, under protection against sunlight. |
MIL-C-17F |
RG 213 /U 50 Ω |
Construction |
Technical data |
Concentric conductors, insulation (dielectric) and sheath. Cable retains its function if inner and external conductor are at exact constant distance, without any cable bending. | ||
Inner conductor: | bare copper, multi wire stranded, diameter 2,25 ± 0,01 mm, 7 x 0,75 mm | |
Insulation (dielectric): | polyethylene, external diameter 7,25 ± 0,05 mm | |
External conductor: | braid of bare copper wires 0,16 mm, 96% optical overlap | |
Sheath: | PVC, external diameter 10,3 ± 0,15 mm | |
sheath colour: | black |
Temperature range: | ||
during installation: |
-15 °C up to +55 °C | |
operating temp.: | -40 °C up to +85 °C | |
Min. inner bending radius: | ||
without load: | 5D (52 mm) | |
under load: | 10D (103 mm) | |
Behaviour in fire: | IEC 60332-1 | |
Maximal tensile strength: | 470 N | |
Cable weight: | 157 kg/km | |
Copper weight: | 87 kg/km | |
Electrical characteristics: | ||
Frequency | Attenuation at 20 °C | Max. permitted strength (at outdoor temperature of 25 °C and max. conductor temperature of 70 °C) |
MHz | dB/100 | W |
10 | 1,8 | 2300 |
100 | 6,8 | 920 |
200 | 9,0 | 570 |
400 | 14,4 | 380 |
1000 | 24,7 | 210 |
1500 | 31,5 | 170 |
2000 | 36,4 | 140 |
3000 | 46,6 | 100 |
5200 | 62,0 | 73 |
5800 | 67,0 | 67 |
Frequency | Losses in return loop |
MHz | dB |
50 - 300 | ≥ 26 |
300 - 1000 | ≥ 23 |