YSLY-CY

Flexible signal cable PVC insulated, with inner sheath, Cu screen and external PVC sheath

alt. mark: YSLY-CY-JZ
YSLY-CY-OZ
YSLY-CY-JB
YSLY-CY-OB

YSLY-CY
Application

Application

Standards

 

Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Screen of braided copper wires serves as protection against electromagnetic impacts and signal disturbances. Resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.

DIN VDE 0245


Datasheet YSLY-CY

Construction

Construction

Construction

Technical data

Conductor: bare copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295
Insulation: PVC compound TI2 acc. to HD 21.1 / DIN VDE 0281 or YI2 acc. to VDE 0207.4, with green-yellow core, always in external layer (≥ 3 cores) or without green-yellow core
core marking: (acc. to DIN VDE 0293) black numbered or coloured
Inner sheath: PVC compound
Screen: braid of tinned copper wires of 0,16 mm diameter, with min 85% overlap
External sheath: PVC compound TM2 acc. to HD 21.1 / DIN VDE 0281 or YM2 acc. to VDE 0207.5
sheath colour: grey (RAL 7001) or transparent
Temperature range:  
during installation:
-5 °C up to +50 °C
fixed installed: -30 °C up to +70 °C
Nominal voltage: Uo /U = 300/500 V
Test voltage: min. 4000 V
Insulation resistance: min. 20 MΩ x km
Min. inner bending radius:  
fixed installed: 6D
at application with bending: 20D
Behaviour in fire: IEC 60332-1


Conductor cross-section Construction of individual conductor Insulation thickness Specific. el. resistance of insulation at 70 °C Conductor resistance at 20 °C
nominal nominal nominal min. max.
mm² n x mm mm MΩ x km Ω/km
0,5 16 x 0,20 0,4 00,13 39
0,75 24 x 0,20 0,4 0,011 26
1 32 x 0,20 0,4 0,01 19,5
1,5 30 x 0,25 0,5 0,009 13,3
2,5 50 x 0,25 0,7 0,008 7,98

Dimensions - number of cores x conductor cross-section External diameter Cu weight Cable weight Packing*
  approx.   approx.  
N x mm² mm kg/km kg/km  
2 x 0,5 7 41 75 CUT
3 x 0,5 7,3 45,5 83 CUT
4 x 0,5 7,9 55 99 CUT
5 x 0,5 8,4 66 112 CUT
7 x 0,5 8,9 80,5 132 CUT
10 x 0,5 10,6 83 170 CUT
12 x 0,5 11,3 138,5 22 CUT
18 x 0,5 13,3 156,4 289 CUT
21 x 0,5 13,9 160 315 CUT
25 x 0,5 15,2 250 378 CUT
30 x 0,5 16,1 297 429 CUT
40 x 0,5 18,2 343 542 CUT
50 x 0,5 20 390 680 CUT
61 x 0,5 21,5 475 780 CUT
 
2 x 0,75 7,4 46 86 CUT
3 x 0,75 7,9 57,9 100 CUT
4 x 0,75 8,4 64 115 CUT
5 x 0,75 8,9 77,4 130 CUT
7 x 0,75 9,7 102 161 CUT
12 x 0,75 12,3 177 247 CUT
18 x 0,75 14,5 243 356 CUT
20 x 0,75 15 230 420 CUT
25 x 0,75 16,6 307,3 465 CUT
34 x 0,75 18,9 323,2 601 CUT
40 x 0,75 20,5 369,4 734 CUT
41 x 0,75 20,6 400 728 CUT
50 x 0,75 22 530 875 CUT
61 x 0,75 23,5 620 150 CUT
 
2 x 1 7,9 56 98 CUT
3 x 1 8,2 65,3 111 CUT
4 x 1 8,7 78,1 130 CUT
5 x 1 9,5 89,4 153 CUT
7 x 1 10,2 113,3 185 CUT
12 x 1 13,3 188,1 37 CUT
16 x 1 14,6 216 390 CUT
18 x 1 15,5 286 418 CUT
25 x 1 17,5 388,5 544 CUT
34 x 1 20,3 505 738 CUT
41 x 1 22 578 864 CUT
50 x 1 23,8 688 1011 CUT
61 x 1 25,3 750 1320 CUT
 
2 x 1,5 8,5 65 117 CUT
3 x 1,5 8,9 83 136 CUT
4 x 1,5 9,6 100 163 CUT
5 x 1,5 10,3 125 188 CUT
7 x 1,5 11,3 196 237 CUT
12 x 1,5 14,8 280 393 CUT
18 x 1,5 17,3 300 535 CUT
21 x 1,5 18 385 635 CUT
25 x 1,5 20,1 535 745 CUT
34 x 1,5 22,8 702 964 CUT
41 x 1,5 24,7 844,6 1123 CUT
50 x 1,5 27,1 1006 1372 CUT
61 x 1,5 28,6 1070 1680 CUT
 
2 x 2,5 9,9 112 22 CUT
3 x 2,5 10,3 146 192 CUT
4 x 2,5 11,3 167 233 CUT
5 x 2,5 12,6 200 283 CUT
7 x 2,5 13,9 288 371 CUT
12 x 2,5 17,6 477,3 585 CUT
18 x 2,5 20,8 490 830 CUT
25 x 2,5 24,6 775 1150 CUT
34 x 2,5 28 990 1475 CUT
42 x 2,5 29,4 1090 1790 CUT

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length